<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>جهاد دانشگاهی-پژوهشکده توسعه صنایع شیمیایی ایران</PublisherName>
				<JournalTitle>نشریه شیمی و مهندسی شیمی ایران</JournalTitle>
				<Issn>1022-7768</Issn>
				<Volume>32</Volume>
				<Issue>4</Issue>
				<PubDate PubStatus="epublish">
					<Year>2013</Year>
					<Month>12</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Measurement of Glutamate Using Biosensor Based on Vertically Aligned Carbon Nanotubes</ArticleTitle>
<VernacularTitle>اندازه‌گیری گلوتامات با استفاده از حسگر زیستی بر پایه نانولوله‌های کربنی عمودی</VernacularTitle>
			<FirstPage>33</FirstPage>
			<LastPage>36</LastPage>
			<ELocationID EIdType="pii">5550</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>اعظم</FirstName>
					<LastName>قلیزاده</LastName>
<Affiliation>تهران، دانشگاه صنعتی شریف، پژوهشکده علوم و فناوری نانو</Affiliation>

</Author>
<Author>
					<FirstName>سعید</FirstName>
					<LastName>شاهرخیان</LastName>
<Affiliation>تهران، دانشگاه صنعتی شریف، پژوهشکده علوم و فناوری نانو</Affiliation>

</Author>
<Author>
					<FirstName>اعظم</FirstName>
					<LastName>ایرجی زاد</LastName>
<Affiliation>تهران، دانشگاه صنعتی شریف، پژوهشکده علوم و فناوری نانو</Affiliation>

</Author>
<Author>
					<FirstName>شمس الدین</FirstName>
					<LastName>مهاجرزاده</LastName>
<Affiliation>تهران، دانشگاه تهران، پردیس دانشکده های فنی، دانشکده برق و کامپیوتر، آزمایشگاه نانوالکترونیک و لایه نازک</Affiliation>

</Author>
<Author>
					<FirstName>منوچهر</FirstName>
					<LastName>وثوقی</LastName>
<Affiliation>تهران، دانشگاه صنعتی شریف، دانشکده مهندسی شیمی و نفت</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2012</Year>
					<Month>09</Month>
					<Day>02</Day>
				</PubDate>
			</History>
		<Abstract>&lt;em&gt;A sensitive glutamate biosensor is prepared based on glutamate dehydrogenase/vertically aligned carbon nanotubes (GLDH, VACNTs). Vertically aligned carbon nanotubes were grown on a silicon substrate by Direct Current Plasma Enhanced Chemical Vapor Deposition (DC-PECVD) method. Glutamate dehydrogenase covalently attached on tip of VACNTs. The electrochemical performance of the electrode for detection of glutamate was investigated by cyclic and differential pulse voltammetry. The linear calibration curve of the concentration of glutamate versus peak current is investigated in a wide range of 0.1–500 &lt;/em&gt;&lt;em&gt;m&lt;/em&gt;&lt;em&gt;M. The mediator-less biosensor has a low detection limit of 57 nM and two linearranges of 0.1–20 &lt;/em&gt;&lt;em&gt;m&lt;/em&gt;&lt;em&gt;M with a sensitivity of 0.976 mA/mM cm&lt;sup&gt;2&lt;/sup&gt; and 20–300 &lt;/em&gt;&lt;em&gt;m&lt;/em&gt;&lt;em&gt;M with a sensitivity of 0.182 mA/mM&lt;/em&gt;&lt;em&gt;.&lt;/em&gt;&lt;em&gt;cm&lt;sup&gt;2&lt;/sup&gt;. The effects of the other biological compounds on the voltammetric behavior of the prepared biosensor and its response stability are investigated. The results are demonstrated that the GLDH/VACNTs electrode even without electron mediator is a suitable basic electrode for detection of glutamate.&lt;/em&gt;</Abstract>
			<OtherAbstract Language="FA">&lt;em&gt;حسگر زیستی حساس گلوتامات با استفاده از گلوتامات دهیدروژناز/ نانولوله‌های کربنی عمودی ساخته شد. نانولوله‌ های کربنی بر روی ویفر سیلیکن با استفاده از روش نشست بخار در پلاسما رشد داده شد. گلوتامات دهیدروژناز به روش کووالانسی روی نوک نانولوله‌ ها تثبیت شد. کارایی حسگر زیستی با استفاده از روش‌های ولتامتری چرخه‌ای و ولتامتری پالسی تفاضلی بررسی شد. منحنی واسنجی در بازه ‌ی وسیع 1/0-500 میکرومولار رسم شد. حسگر زیستی بدون استفاده از واسطه حد تشخیص 57 نانومولار دارد و حساسیت آن در بازه‌ی 1/0- 20 میکرومولار، &lt;sup&gt;2&lt;/sup&gt;&lt;/em&gt;&lt;em&gt;mAm/Mcm&lt;/em&gt;&lt;em&gt;  976/0 و در بازه ‌ی 20-300 میکرومولار، &lt;/em&gt;&lt;em&gt;mAm/Mcm&lt;/em&gt;&lt;em&gt; 182/0 است. اثر بقیه مواد زیستی بر روی رفتار ولتامتر حسگر زیستی و همچنین پایداری پاسخ‌ها بررسی شد. نتیجه‌ ها نشان داد که این حسگر زیستی حتی بدون استفاده از واسطه با حساسیت بالا می‌ تواند گلوتامات را اندازه گیری کند.&lt;/em&gt;</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">نانولوله‌های کربنی عمودی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">حسگر زیستی الکتروشیمیایی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">ولتامتری پالسی تفاضلی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">گلوتامات</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.nsmsi.ir/article_5550_e68879a4839773d105f0689875dace83.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
